How to Confirm a Supplier Site Sits Inside an Earthquake's Shaking Zone

A quake hits, and within an hour your team has a list of twelve named sites somewhere in the affected region. The question isn't abstract: which of those twelve sat inside the strong-shaking zone, and which were far enough out that you can probably stop worrying about them. Getting that answer right shapes whether you reroute an order today or wait for a supplier to call you back.
Shaking intensity is not the same thing as your supplier footprint
The USGS ShakeMap (or your region's equivalent, JMA intensity in Japan, EMSC in Europe) publishes a grid of shaking intensity, usually as Modified Mercalli Intensity (MMI) contours or peak ground acceleration values, within minutes of a quake. That grid tells you how hard the ground shook at a given point. It says nothing about what's sitting on that point.
Your supplier footprint is a list of addresses, lat/longs, maybe a GeoJSON export from your supplier risk system. Neither dataset talks to the other on its own. A site inside MMI VII (very strong shaking) might be a reinforced plant that rode it out fine. A site at the edge of MMI V might sit on fill soil and have real damage. Intensity tells you exposure. It doesn't tell you outcome.
Overlaying the shaking grid against named sites
The mechanics are straightforward once you have both layers:
- Pull the ShakeMap shapefile or raster for the event, usually available within 15 to 30 minutes of a significant quake.
- Plot your named sites as points over it, by coordinate, not by city or postal code. A supplier's registered mailing address is frequently in a different part of town from the actual plant or warehouse.
- Read off the MMI or PGA value under each point.
- Flag anything inside, say, MMI VI and above for closer attention. The exact cutoff depends on your own risk appetite and the construction types you're dealing with.
That gives you an exposure list within the hour. It's a real improvement over waiting on supplier self-reports, and it's the step most control towers already do, or should. But it answers "did this site feel strong shaking," not "is this site still standing." For allocation and claims decisions, that second question is the one that actually moves money.
Why an intensity grade isn't a damage call
Two sites can sit under the same MMI VII contour and come out completely differently. Soil type, building age, retrofit history, and whether the roof was already compromised before the quake all matter more than the grid value alone. A control tower that stops at "inside the VII zone, flag it" ends up treating a site with a cracked parking lot the same as one with a collapsed roof bay, because the shaking data can't tell them apart.
This is where a lot of teams get stuck for days. The shaking map arrives fast. What it actually did to the roofline, the loading dock, the yard, takes a field adjuster, a supplier's own survey, or someone looking at the site directly. None of those are quick.
That gap, between knowing a site was inside the footprint and knowing what the footprint did to it, is the part that still runs on phone calls and waiting. Supplier Impact Assessment was built to close that gap: it checks each named site against the event footprint and tells you whether there's visible damage, on a per-site basis, instead of a regional intensity grade applied to everyone the same way.
A quick reference for what each layer can tell you
- ShakeMap / intensity grid: how hard the ground shook at a point, available within the hour, no information about structures.
- Supplier footprint overlay: which named sites sat inside which intensity band, still no information about structures.
- Site-level imagery check: whether there's visible damage at each specific site, which is the piece that was previously only available days later.
If a quake just put one of your named sites somewhere inside its shaking footprint, it's worth checking what that site actually looks like rather than guessing from the intensity grade alone.